EASE OF OPERATION
ADVANCED DELIVERY CATHETER
Delivery catheter with flexible distal tip
- Enhanced trackability in challenging anatomy
Pin and pull delivery system
- Designed for ease of use by a single operator
Stent placement accuracy
- Fully repositionable with up to 50% deployment7
- Allows the users to reposition the stent if needed7
GROWING BODY OF CLINICAL EVIDENCE
Over 3,000 patients studied
Clinical evidence
The CLEAR-ROAD study: evaluation of a new dual layer micromesh stent system for the carotid artery.
Bosiers M, Deloose K, Torsello G, Scheinert D, Lieven M, Peeters M, MD, Müller-Hülsbeck S, Sievert H, Langhoff R, Bosiers M, Setacci C EuroIntervention. 2016;12(5):e671-6.
The CLEAR-ROAD study: evaluation of a new dual layer micromesh stent system for the carotid artery.
Bosiers M, Deloose K, Torsello G, Scheinert D, Lieven M, Peeters M, MD, Müller-Hülsbeck S, Sievert H, Langhoff R, Bosiers M, Setacci C EuroIntervention. 2016;12(5):e671-6.
See all clinical evidence
General specifications
Stent platform
Construction | Double layer, braided mesh |
---|
Material | Nitinol |
---|
Stent delivery system
Guidewire compatibility | 0.014" (0.36 mm) |
---|
Introducer sheath compatibility | 5 Fr (I.D. > 0.074'") |
---|
Delivery system construction | rapid exchange (RX), segment length 25 cm |
---|
Usable catheter length | 143 cm |
---|
Item specifications
Stent diameter | Micromesh layer stent length | Overall stent length | Vessel Ø 1 mm smaller than unconstrained Ø | Vessel Ø 2 mm smaller than unconstrained Ø |
Vessel diameter | Micromesh layer length | Overall length | Vessel diameter | Micromesh layer length | Overall length |
RDS-0520-143RX | 5 | 20 | 25 | 4 | 20 | 33 | 3 | 22 | 35 |
RDS-0530-143RX | 5 | 30 | 37 | 4 | 35 | 47 | 3 | 38 | 52 |
RDS-0540-143RX | 5 | 40 | 47 | 4 | 45 | 59 | 3 | 52 | 64 |
RDS-0616-143RX | 6 | 16 | 22 | 5 | 20 | 32 | 4 | 23 | 35 |
RDS-0625-143RX | 6 | 25 | 33 | 5 | 30 | 44 | 4 | 33 | 48 |
RDS-0630-143RX | 6 | 30 | 40 | 5 | 40 | 53 | 4 | 43 | 58 |
RDS-0718-143RX | 7 | 18 | 25 | 6 | 23 | 35 | 5 | 26 | 38 |
RDS-0725-143RX | 7 | 25 | 35 | 6 | 30 | 47 | 5 | 36 | 52 |
RDS-0730-143RX | 7 | 30 | 40 | 6 | 40 | 53 | 5 | 44 | 60 |
RDS-0820-143RX | 8 | 20 | 25 | 7 | 25 | 36 | 6 | 27 | 40 |
RDS-0825-143RX | 8 | 25 | 35 | 7 | 30 | 49 | 6 | 38 | 54 |
RDS-0830-143RX | 8 | 30 | 40 | 7 | 40 | 55 | 6 | 45 | 61 |
RDS-0840-143RX | 8 | 40 | 47 | 7 | 50 | 67 | 6 | 60 | 75 |
RDS-0920-143RX | 9 | 20 | 33 | 8 | 30 | 45 | 7 | 33 | 48 |
RDS-0930-143RX | 9 | 30 | 40 | 8 | 40 | 55 | 7 | 45 | 60 |
RDS-1020-143RX | 10 | 20 | 35 | 9 | 30 | 45 | 8 | 35 | 50 |
RDS-1030-143RX | 10 | 30 | 43 | 9 | 40 | 55 | 8 | 45 | 60 |
*The ROADSAVER Carotid Stent System is indicated for use in patients with carotid artierial atherosclerotic disease. Refer to instructions for use, contraindications and warnings for additional information. Roadsaver is manufactured by MicroVention Europe and distributed by Terumo Europe N.V. All brand names are a Trademark or registered trademarks of TERUMO CORPORATION and their respective owners. CE 0297
References
- DATA ON FILE Microvention Inc.
- Hopf-Jensen, S. et al.. Initial clinical experience with the micromesh Roadsaver carotid artery stent for the treatment of patients with symptomatic carotid artery disease. J Endovasc Ther 22, 220–5 (2015).
- Nerla, R. et al. Carotid artery stenting with a new-generation double-mesh stent in three high-volume Italian centres: clinical results of a multidisciplinary approach. EuroIntervention 12, e677-83 (2016).
- Hopf-Jensen, S. et al. Initial clinical experience with the micromesh Roadsaver carotid artery stent for the treatment of patients with symptomatic carotid artery disease. J Endovasc Ther 22, 220–5 (2015).
- Kedev, S. et al. Safety of Slender 5Fr Transradial Approach for Carotid Artery Stenting With a Novel Nitinol Double-Layer Micromesh Stent. Am J Cardiol 116, 977–81 (2015).
- Ruffino, M. A. et al. Early Embolization After Carotid Artery Stenting with Mesh-Covered Stent: Role of Diffusion-Weighted Magnetic Resonance Imaging as Pre-procedural Predictor and Discriminant Between Intra- and Post-procedural Events. Cardiovasc Intervent Radiol 42, 812–819 (2019).
- PD110729 Roadsaver Instructions for use.